If the bearing of the generator lacks oil or is poorly lubricated, the rolling resistance of the bearing will be too large, and the outer race and inner race of the bearing will rotate synchronously, which will lead to excessive wear between the bearing and the bearing seat. Excessive bearing wear will cause friction between the rotor and stator of the generator, resulting in overheating of the generator and instability of the voltage and current of the generator.
Check the generator bearing for lack of oil or poor lubrication
4. Check the heralces telehandler, length of the carbon brush. If the length of the carbon brush is less than 5mm, replace it in time.
Check the length of the carbon brush
The heracles H280E carbon brush on the generator plays a very important role. The current is generated by the carbon brush, slip ring and exciting coil, and the generator generates electricity by cutting the magnetic field through the coil. If there is a problem with the carbon brush, the generator will not produce a magnetic field. Without a magnetic field, there is no way to generate electricity. In addition, if brushless generator is adopted, the H140 kingway heracles, h140 heracles loader length of carbon.brush can be ignored. www.heraclesloader.com